- VoltAlert™ technology for non-contact voltage detection.
- AutoVolt automatic ac/dc voltage selection.
- Low input impedance: Helps prevent false readings due to ghost voltage.
- Large white LED backlight to work in poorly lit areas.
- True-rms for accurate measurements on non-linear loads.
- Measures 10 A (20 A overload for 30-seconds).
- Resistance, continuity, frequency and capacitance.
- Min/Max/Average to record signal fluctuations.
- Compact ergonomic design for one-handed operation.
- CAT III 600 V safety rated.
- 400 A ac current measurement.
- 600 V ac and dc voltage measurement.
- True-rms ac voltage and current for accurate measurements on non-linear signals.
- Resistance measurement up to 40 kΩ with continuity detection.
- Slim, ergonomic design.
- CAT IV 300V/CAT III 600 V safety ratin
| Specifications | ||
| Maximum voltage between any terminal and earth ground | 600 V | |
| Surge protection | 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 | |
| Fuse for A input | 11 A, 1000 V FAST Fuse (Fluke PN 803293) | |
| Display | Digital: | 6,000 counts, updates 4 per second |
| Bar graph | 33 segments, updates 32 per second | |
| Operating Temperature | -10 °C to + 50 °C | |
| Storage Temperature | -40 °C to + 60 °C | |
| Battery type | 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 | |
| Battery Life | 400 hours typical, without backlight | |
| Accuracy Specifications | ||
| DC millivolts | Range | 600.0 mV |
| Resolution | 0.1 mV | |
| Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 | |
| DC volts | Range/Resolution | 6.000 V / 0.001 V |
| Range/Resolution | 60.00 V / 0.01 V | |
| Range/Resolution | 600.00 V / 0.1 V | |
| Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 | |
| Auto volts | Range | 600.0 V |
| Resolution | 0.1 V | |
| Accuracy | 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) |
|
| AC millivolts1 true-rms | Range | 600.0 mV |
| Resolution | 0.1 mV | |
| Accuracy | 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
|
| AC volts1 true-rms | Range/Resolution | 6.000 V / 0.001 V |
| Range/Resolution | 60.00 V / 0.01 V | |
| Range/Resolution | 600.0 V / 0.1 V | |
| Accuracy | 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
|
| Continuity | Range | 600 Ω |
| Resolution | 1 Ω | |
| Accuracy | Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer. | |
| Ohms | Range/Resolution | 600.0 Ω / 0.1 Ω |
| Range/Resolution | 6.000 kΩ / 0.001 kΩ | |
| Range/Resolution | 60.00 kΩ / 0.01 kΩ | |
| Range/Resolution | 600.0 kΩ / 0.1 kΩ | |
| Range/Resolution | 6.000 MΩ / 0.001 MΩ | |
| Accuracy | 0.9 % + 1 | |
| Range/Resolution | 40.00 MΩ / 0.01 MΩ | |
| Accuracy | 5 % + 2 | |
| Diode Test | Range/Resolution | 2.000 V / 0.001 V |
| Accuracy | 0.9% + 2 | |
| Capacitance | Range/Resolution | 1000 nF / 1 nF |
| Range/Resolution | 10.00 μF / 0.01 μF | |
| Range/Resolution | 100.0 μF / 0.1 μF | |
| Range/Resolution | 9999 μF / 1 μF | |
| Range/Resolution | 100 μF to 1000 μF | |
| Accuracy | 1.9% + 2 | |
| Range/Resolution | > 1000 μF | |
| Accuracy | 5% + 20% | |
| LoZ capacitance | Range | 1 nF to 500 μF |
| Accuracy | 10% + 2 typical | |
| AC amps true-rms (45 Hz to 500 Hz) | Range/Resolution | 6.000 A / 0.001 A |
| Range/Resolution | 10.00 A / 0.01 A | |
| Accuracy | 1.5% + 3 20 A continuous overload for 30 seconds max |
|
| DC amps | Range/Resolution | 6.000 A / 0.001 A |
| Range/Resolution | 10.00 A / 0.01 A | |
| Accuracy | 1.0% + 3 20 A continuous overload for 30 seconds max |
|
| Hz (V or A input)2 | Range/Resolution | 99.99 Hz / 0.01 Hz |
| Range/Resolution | 999.99 Hz / 0.1 Hz | |
| Range/Resolution | 9.999 Hz / 0.001 Hz | |
| Range/Resolution | 50.00 Hz / 0.01 Hz | |
| Accuracy | 0.1% + 2 | |
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
| Mechanical & General Specifications | |
| Size | 167 x 84 x 46 mm (6.57" x 3.31" x 1.82") |
| Weight | 550 g |
| Warranty | 3 years |
Fluke 323 True-rms Clamp Meter
| Specifications | ||
| AC current | Range 400.0 A | |
| Accuracy | 2 % ± 5 digits (45 Hz to 65 Hz) 2.5 % ± 5 digits (65 Hz to 400 Hz) |
|
| AC voltage | Range | 600.0 V |
| Accuracy | 1.5 % ± 5 digits | |
| DC voltage | Range | 600.0 V |
| Accuracy | 1.0 % ± 5 digits | |
| Resistance | Range | 400.0 Ω/ 4000 Ω |
| Accuracy | 1.0 % ± 5 digits | |
| Continuity | ≤ 70 Ω | |
| AC response | True-rms | |
| Data hold | Yes | |
| Size | H x W x D (mm) | 207 x 75 x 34 |
| Max wire diameter | 30 mm (600 MCM) | |
| Weight | 265 g | |
| Category rating | CAT III 600 V CAT IV 300 V | |