Jual Fluke 116 Multimeter with Temperature - Supplier Alat Safety, Alat Teknik, Alat Ukur, Alat Geologi, Sirine dan Alat Laboratorium

Jual Fluke 116 Multimeter with Temperature

Features :


  • Built-in thermometer for HVAC applications
  • Microamps to test flame sensors
  • Low input impedance: helps prevent false readings due to ghost voltage
  • Large white LED backlight to work in poorly lit areas
  • Resistance, continuity, frequency and capacitance
  • Min/Max/Average with elapsed time to record signal fluctuations
  • Compact ergonomic design for one-handed operation
  • Compatible with optional magnetic hanger (ToolPak™)
  • CAT III 600 V safety rated
Spesifications:

Maximum voltage between any terminal and earth ground

 600 V
Surge protection

 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display
Digital:  6,000 counts, updates 4 per second
Bar graph

 33 segments, updates 32 per second
Operating Temperature

 -10 °C to + 50 °C
Storage Temperature

 -40 °C to + 60 °C
Battery type

 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life

 400 hours typical, without backlight
Accuracy Specifications
DC millivolts
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.00 V / 0.1 V
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
Auto volts
Range:  600.0 V
Resolution:  0.1 V
Accuracy:  2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.0 V / 0.1 V
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range:  600 Ω
Resolution:  1 Ω
Accuracy:  Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms
Range/Resolution:  600.0 Ω / 0.1 Ω
Range/Resolution:  6.000 kΩ / 0.001 kΩ
Range/Resolution:  60.00 kΩ / 0.01 kΩ
Range/Resolution:  600.0 kΩ / 0.1 kΩ
Range/Resolution:  6.000 MΩ / 0.001 MΩ
Accuracy:  0.9 % + 1
Range/Resolution:  40.00 MΩ / 0.01 MΩ
Accuracy:  1.5 % + 2
Diode Test
Range/Resolution:  2.000 V / 0.001 V
Accuracy:  0.9% + 2
Capacitance
Range/Resolution:  1000 nF / 1 nF
Range/Resolution:  10.00 μF / 0.01 μF
Range/Resolution:  100.0 μF / 0.1 μF
Range/Resolution:  9999 μF / 1 μF
Range/Resolution:  100 μF to 1000 μF
Accuracy:  1.9% + 2
Range/Resolution:  > 1000 μF
Accuracy:  5% + 20%
LoZ capacitance
Range:  1 nF to 500 μF
Accuracy:  10% + 2 typical
Temperature2 (Type-K thermocouple)
Range/Resolution:  -40 °C to 400 °C / 0.1 °C
Accuracy:  1% + 102
Range/Resolution:  -40 °F to 752 °F / 0.2 °F
Accuracy:  1% + 182
AC μamps true-rms (45 Hz to 500 Hz)
Range/Resolution:  600.0 μA / 0.1 μA
Accuracy:  1.0% + 2
DC μamps
Range/Resolution:  600.0 μA / 0.1 μA
Accuracy:  1.0% + 2
Hz (V or A input)2
Range/Resolution:  99.99 Hz / 0.01 Hz
Range/Resolution:  999.99 Hz / 0.1 Hz
Range/Resolution:  9.999 Hz / 0.001 Hz
Range/Resolution:  50.00 Hz / 0.01 Hz
Accuracy:  0.1% + 2
Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F

Mechanical & General Specifications
Size

 167 x 84 x 46 mm (6.57" x 3.31" x 1.82")
Weight

 550 g

Related product you might see:

Share this product :

Posting Komentar

 
Support : Creating Website | Johny Template | Mas Template
Copyright © 2011. Supplier Alat Safety, Alat Teknik, Alat Ukur, Alat Geologi, Sirine dan Alat Laboratorium - All Rights Reserved
Template Created by Creating Website Published by Mas Template
Proudly powered by Blogger