JUAL APPA 106 DIGITAL MULTIMETER - Supplier Alat Safety, Alat Teknik, Alat Ukur, Alat Geologi, Sirine dan Alat Laboratorium

JUAL APPA 106 DIGITAL MULTIMETER

 
APPA 106 DIGITAL MULTIMETER
Harga : Rp 2,250,000 

Features :
  • 4000 count digital display
  • 82-segment analogue bargraph display
  • data-hold function
  • relative measuring mode
  • min/ max/ avg function
  • peak hold
  • continuity check/ beeper
  • backlight
  • open communication protocol
  • water and dust-resistant
  • protective holster
  • true RMS
Specifications
 Voltage AC
  APPA 103N
  Range:                                   400.0mV~750V
  Basic Accuracy:                 +/-(1.3%+5d)
  APPA 105N, 106  Range:                                   400.0mV~750V
  Basic Accuracy:                 +/-(1.0%+5d)
  APPA 107N, 109N
  Range:
                                   400.0mV~750V
  Basic Accuracy:                 +/-(0.7%+5d)

  APPA 103N, 105N  Conversion Type:                Average sensing RMS indicating
  APPA 106
  Conversion Type:
                True RMS reading on AC mode
  APPA 107N, 109N  Conversion Type:               (AC+DC) True RMS reading on AC mode
                                                  ACV spec. +1.00%+8d

  Input Impedance:               10M?//100pF
  
  APPA 103N, 105N, 106
  Frequency Resonse:
         40Hz~1kHz
  APPA 107N
  Frequency Response:      
40Hz~50kHz
  APPA 109N
  Frequency Response:
       40Hz~100kHz

  Overload Protection:         1000V DC or 750V rms
 Voltage DC
  APPA 103N
  Range:                                   400.0mV~1000V
  Basic Accuracy:                 +/-(0.25%+1d)
  APPA 105N, 106  Range:                                   400.0mV~1000V
  Basic Accuracy:                 +/-(0.1%+1d)
  APPA 107N, 109N
  Range:
                                   400.0mV~1000V
  Basic Accuracy:                 +/-(0.06%+10d)

  Input Impedance:               10M?
  
  Overload Protection:         1000V DC or 750V rms
 Current AC
  APPA 103N, 105N, 106
  Range:                                   40.00mA~10A
  Basic Accuracy:                 +/-(1.3%+5d)
  APPA 107N, 109N
  Range:
                                   40.00mA~10A
  Basic Accuracy:                 +/-(0.8%+50d)

  APPA 103N, 105N  Conversion Type:                Average sensing RMS indicating
  APPA 106
  Conversion Type:
                True RMS reading on AC mode
  APPA 107N, 109N  Conversion Type:               (AC+DC) True RMS reading on AC mode
                                                  ACV spec. +1.00%+8d

  APPA 103N, 105N, 106
  Frequency Resonse:
         40Hz~1kHz
  APPA 107N, 109N
  Frequency Response:      
40Hz~3kHz

  Input Protection:                 Equipped with High Energy Fuse.
                                                  1A, 600V, IR 10KV fuse for mA input
                                                  15A, 600V, IR 100KV fuse for A input
 Current DC
  APPA 103N, 
  Range:                                   40.00mA~10A
  Basic Accuracy:                 +/-(0.6%+2d)

  APPA 105N, 106
  Range:
                                   40.00mA~10A
  Basic Accuracy:                 +/-(0.4%+2d)

  APPA 107N, 109N
  Range:
                                   40.00mA~10A
  Basic Accuracy:                 +/-(0.2%+40d)
 
  Input Protection:                 Equipped with High Energy Fuse.
                                                  1A, 600V, IR 10KV fuse for mA input
                                                  15A, 600V, IR 100KV fuse for A input
 Resistance
  APPA 103N
  Range:                                   400.0?~40.00M?
  Basic Accuracy:                 +/-(0.6%+2d)
  APPA 105N, 106  Range:                                   400.0?~40.00M?
  Basic Accuracy:                 +/-(0.4%+2d)
  APPA 107N, 109N
  Range:
                                   400.0?~40.00M?
  Basic Accuracy:                 +/-(0.3%+30d)

  Overload Protection:         600V rms
 Continuity Beeper
   APPA 103N, 105N, 106 
  
<50?, 2k Hz tone buzzer

   APPA 107N, 109N
   <150?, 2k Hz tone buzzer
 Diode Test
  APPA 103N, 105N, 106
  Open circuit voltage:
        3V

  APPA 107N, 109N
  Open circuit voltage:        3.3V
 Capacitace
  APPA 103N, 105N, 106
  Range:                                   4.000nF~10mF
  Basic Accuracy:                 +/-(2.0%+5d)
  APPA 107N, 109N
  Range:
                                   4.000nF~10mF
  Basic Accuracy:                 +/-(0.9%+5d)

  Overload Protection:         600V rms
 Frequency Counter
  APPA 103N, 105N, 106
  Range:
                                   4kHz~400MHz
  Basic Accuracy:                 +/-(0.01%+1d)
  APPA 107N,  109N
  Range:
                                   20.00Hz~1MHz
  Basic Accuracy:                 +/-(0.01%+10d)
                                               
  Overload Protection:         600V rms
 RPM  
  APPA 103N, 105N, 106
  Range:
                                   40kRPM~400kRPM
  Basic Accuracy:                 +/-(0.01%+10d)
                                                 
  Overload Protection:         600V rms
 Duty Factor
  APPA 107N, 109N
  Range:
                                  20%~80%
  Basic Accuracy:                +/-1%

 Temperature
  APPA 106
  Range:
                                   -20?~800?  Basic Accuracy:                 +/-(2%+2?) at 351?~500?
  APPA 107N, 109N
  Range:
                                   -200?~1200?
 
Basic Accuracy:                 +/-(0.1%+3?) at -100?~1200?

  Overload Protection          600V rms
 General Specifications
 Display
  APPA 103N, 105N, 106
 
4000 count, 82 segment analog bargraph
  APPA 107N, 109N
  20000count/4000 count , 83 segment analog bar graph
 Measuring Rate
  APPA 103N, 105N, 106
  2.5times/sec for 4000 count and 20 times/sec for analog bargraph
  APPA 107N, 109N  2times/sec for 20000 count, 4times/sec for 4000 count, and 20times/
  sec for analog bargraph
 Overload Indication
 

 
 Auto Power Off
  
"OL" or "-OL"
 Operating Temperature
 
-20?~ 50?, <80% RH
 Storage Temperature  
 
-20?~ 60?
 Temperature Coefficient
 
0.15(Spec. Acc)/?, <18? or >28? 
 Safety
 
IEC61010 and designed to meet UL61010 specifications
 Power Requirement

  APPA 107N, 109N
  IEC 6LF22, 6AM6 or NEDA 1604A 9V x1
  APPA 103N, 105N  IEC LR03, AM4 or AAA size 1.5V x 2.
 Battery Life
  APPA 103N, 105N
  450 hours (Alkaline)
  APPA 106   300 hours (Alkaline)
  APPA 107N, 109N
  100 hours (Alkaline)

 
 Size
  86mm (W) x 185mm (L) x 31.5mm (H)
  98mm (W) x 197mm (L) x 50mm (H) with holster
 Weight
  620 grams
 Included with Instrument
  Protective holster, test leads, test clips, ZnC battery(Installed),
  manual, Optical RS-232 cable(109N), and WinDMM 100S(109N)
Free Ongkir wilayah Jakarta & Tangerang dan sekitarnya

Melayani pemesanan untuk dalam dan luar kota

Untuk informasi dan pemesanan hubungi :

KARYA NUSATAMA

Contact Person: Yoga Sutama

Tlp : 02149722589

Esia Mobile :: 02193096961

Mobile : 085880111657


Email : yogakarya1@yahoo.co.id

Gmail : yogakarya3@gmail.com

YM : yogakarya2

Website : http://www.karyanusatama.com

Link : http://digitalmeter.indonetwork.co.id

Related product you might see:

Share this product :

Posting Komentar

 
Support : Creating Website | Johny Template | Mas Template
Copyright © 2011. Supplier Alat Safety, Alat Teknik, Alat Ukur, Alat Geologi, Sirine dan Alat Laboratorium - All Rights Reserved
Template Created by Creating Website Published by Mas Template
Proudly powered by Blogger