Features :
- 4000 count digital display
- 82-segment analogue bargraph display
- data-hold function
- relative measuring mode
- min/ max/ avg function
- peak hold
- continuity check/ beeper
- backlight
- open communication protocol
- water and dust-resistant
- protective holster
- true RMS
Specifications |
|
Voltage AC |
APPA 103N Range: 400.0mV~750V
Basic Accuracy: +/-(1.3%+5d)
APPA 105N, 106 Range: 400.0mV~750V
Basic Accuracy: +/-(1.0%+5d)
APPA 107N, 109N Range: 400.0mV~750V
Basic Accuracy: +/-(0.7%+5d)
APPA 103N, 105N Conversion Type: Average sensing RMS indicating
APPA 106 Conversion Type: True RMS reading on AC mode
APPA 107N, 109N Conversion Type: (AC+DC) True RMS reading on AC mode
ACV spec. +1.00%+8d
Input Impedance: 10M?//100pF
APPA 103N, 105N, 106 Frequency Resonse: 40Hz~1kHz
APPA 107N Frequency Response: 40Hz~50kHz
APPA 109N Frequency Response: 40Hz~100kHz
Overload Protection: 1000V DC or 750V rms |
Voltage DC |
APPA 103N Range: 400.0mV~1000V
Basic Accuracy: +/-(0.25%+1d)
APPA 105N, 106 Range: 400.0mV~1000V
Basic Accuracy: +/-(0.1%+1d)
APPA 107N, 109N Range: 400.0mV~1000V
Basic Accuracy: +/-(0.06%+10d)
Input Impedance: 10M?
Overload Protection: 1000V DC or 750V rms |
Current AC |
APPA 103N, 105N, 106 Range: 40.00mA~10A
Basic Accuracy: +/-(1.3%+5d)
APPA 107N, 109N Range: 40.00mA~10A
Basic Accuracy: +/-(0.8%+50d)
APPA 103N, 105N Conversion Type: Average sensing RMS indicating
APPA 106 Conversion Type: True RMS reading on AC mode
APPA 107N, 109N Conversion Type: (AC+DC) True RMS reading on AC mode
ACV spec. +1.00%+8d
APPA 103N, 105N, 106 Frequency Resonse: 40Hz~1kHz
APPA 107N, 109N Frequency Response: 40Hz~3kHz
Input Protection: Equipped with High Energy Fuse.
1A, 600V, IR 10KV fuse for mA input
15A, 600V, IR 100KV fuse for A input |
Current DC |
APPA 103N, Range: 40.00mA~10A
Basic Accuracy: +/-(0.6%+2d)
APPA 105N, 106 Range: 40.00mA~10A
Basic Accuracy: +/-(0.4%+2d)
APPA 107N, 109N Range: 40.00mA~10A
Basic Accuracy: +/-(0.2%+40d)
Input Protection: Equipped with High Energy Fuse.
1A, 600V, IR 10KV fuse for mA input
15A, 600V, IR 100KV fuse for A input |
Resistance |
APPA 103N Range: 400.0?~40.00M?
Basic Accuracy: +/-(0.6%+2d)
APPA 105N, 106 Range: 400.0?~40.00M?
Basic Accuracy: +/-(0.4%+2d)
APPA 107N, 109N Range: 400.0?~40.00M?
Basic Accuracy: +/-(0.3%+30d)
Overload Protection: 600V rms |
Continuity Beeper |
APPA 103N, 105N, 106 <50?, 2k Hz tone buzzer
APPA 107N, 109N
<150?, 2k Hz tone buzzer |
Diode Test |
APPA 103N, 105N, 106 Open circuit voltage: 3V
APPA 107N, 109N
Open circuit voltage: 3.3V |
Capacitace |
APPA 103N, 105N, 106 Range: 4.000nF~10mF
Basic Accuracy: +/-(2.0%+5d)
APPA 107N, 109N Range: 4.000nF~10mF
Basic Accuracy: +/-(0.9%+5d)
Overload Protection: 600V rms |
Frequency Counter |
APPA 103N, 105N, 106 Range: 4kHz~400MHz
Basic Accuracy: +/-(0.01%+1d)
APPA 107N, 109N Range: 20.00Hz~1MHz
Basic Accuracy: +/-(0.01%+10d)
Overload Protection: 600V rms |
RPM |
APPA 103N, 105N, 106 Range: 40kRPM~400kRPM
Basic Accuracy: +/-(0.01%+10d)
Overload Protection: 600V rms |
Duty Factor |
APPA 107N, 109N Range: 20%~80%
Basic Accuracy: +/-1%
|
Temperature |
APPA 106 Range: -20?~800? Basic Accuracy: +/-(2%+2?) at 351?~500? APPA 107N, 109N Range: -200?~1200? Basic Accuracy: +/-(0.1%+3?) at -100?~1200?
Overload Protection 600V rms |
|
|
General Specifications |
|
Display |
APPA 103N, 105N, 106 4000 count, 82 segment analog bargraph
APPA 107N, 109N
20000count/4000 count , 83 segment analog bar graph |
Measuring Rate |
APPA 103N, 105N, 106 2.5times/sec for 4000 count and 20 times/sec for analog bargraph
APPA 107N, 109N 2times/sec for 20000 count, 4times/sec for 4000 count, and 20times/
sec for analog bargraph |
Overload Indication |
|
Auto Power Off |
"OL" or "-OL" |
Operating Temperature |
-20?~ 50?, <80% RH |
Storage Temperature |
-20?~ 60? |
Temperature Coefficient |
0.15(Spec. Acc)/?, <18? or >28? |
Safety |
IEC61010 and designed to meet UL61010 specifications
|
Power Requirement |
APPA 107N, 109N IEC 6LF22, 6AM6 or NEDA 1604A 9V x1
APPA 103N, 105N IEC LR03, AM4 or AAA size 1.5V x 2. |
Battery Life |
APPA 103N, 105N 450 hours (Alkaline)
APPA 106 300 hours (Alkaline)
APPA 107N, 109N
100 hours (Alkaline)
|
Size |
86mm (W) x 185mm (L) x 31.5mm (H)
98mm (W) x 197mm (L) x 50mm (H) with holster |
Weight |
620 grams |
Included with Instrument |
Protective holster, test leads, test clips, ZnC battery(Installed),
manual, Optical RS-232 cable(109N), and WinDMM 100S(109N) |
|